Alltrax Blink Codes

SR Blink Codes

The throttle code blinks on controller power up and alarm codes blink when

the alarm happens. All alarms are self clearing so when the alarm event is over,
the controller resumes normal operation, except for the Short Circuit alarm that
needs a power off cycle to clear the alarm.

Throttle codes:
1 Green LED Flash  =  0-5k throttle
2 Green LED Flash  =  5K-0 throttle
3 Green LED Flash  =  0-5V throttle
4 Green LED Flash  =  EZGO ITS throttle
5 Green LED Flash  =  0-1k Yamaha throttle
6 Green LED Flash  =  6 to 10.5 Taylor Dunn throttle
7 Green LED Flash  =  Club Car 5k-0 3 wire throttle
8 Green LED Flash  =  Reserved
9 Green LED Flash  =  Pump
10 Green LED Flash  =  USB Throttle
11 Green LED Flash  =  Absolute Throttle

Normal Display Status:

Solid Green Light=Controller Ready to Run
Solid Red Light=Controller in programming mode
Solid Yellow Light=Throttle is wide open and the controller is NOT in Current Limit
Blinking Yellow Light=Throttle is wide open, but the controller is in Current Limit

Error Codes:
SR error codes are different than the AXE/DCX alarm codes in that they will flash Green and Red, instead of just Red.
1 Green and 1 Red LED Flash  =  Short Circuit
1 Green and 2 Red LED Flash  =  Battery Under Voltage
1 Green and 3 Red LED Flash  =  Battery Over Voltage
1 Green and 4 Red LED Flash  =  M- Over temperature
1 Green and 5 Red LED Flash  =  Bus Bar Over temperature
1 Green and 6 Red LED Flash  =  Pre-charge Failure
2 Green and 1 Red LED Flash  =  Under Temp
2 Green and 2 Red LED Flash  =  Not Used
2 Green and 3 Red LED Flash  =  High Throttle Over range
2 Green and 4 Red LED Flash  =  High Throttle Under range
2 Green and 5 Red LED Flash  =  Low Throttle Over range
2 Green and 6 Red LED Flash  =  Low Throttle Under range
3 Green and 1 Red LED Flash  =  Uncalibrated throttle
3 Green and 2 Red LED Flash  =  Bad Variable Set Loaded

---------------------------------------------------------------

XCT Blink Codes

On power up, the controller will blink out a throttle code and then a Status or
Error Code (see below)
Throttle codes:
1 Green LED Flash  =  0-5k throttle
2 Green LED Flash  =  5K-0 throttle
3 Green LED Flash  =  0-5V throttle
4 Green LED Flash  =  EZGO ITS throttle
5 Green LED Flash  =  Club Car, G19, G22
6 Green LED Flash  =  6 to 10.5 Taylor Dunn throttle
7 Green LED Flash  =  Reserved
8 Green LED Flash  =  Reserved
9 Green LED Flash  =  Pump
10 Green LED Flash  =  USB Throttle
11 Green LED Flash  =  Absolute Throttle

Normal display status:

Solid Green Light = Controller Ready to Run
Solid Red Light = Controller in programming mode
Solid Yellow Light = Throttle is wide open and the controller is NOT in Current Limit
Blinking Yellow Light = Throttle is wide open, but the controller is in Current Limit

Error Codes:
XCT/NCT Alarm Codes flash a number of times green then red. All alarms are self clearing and will repeat until the error condition has been corrected.
1 Green and 1 Red LED Flash  =  Short Circuit/Output Fault
1 Green and 2 Red LED Flash  =  Battery Under Voltage
1 Green and 3 Red LED Flash  =  Battery Over Voltage
1 Green and 4 Red LED Flash  =  Over temperature
1 Green and 5 Red LED Flash  =  Motor Field Failure
1 Green and 6 Red LED Flash  =  Pre-charge Failure
2 Green and 1 Red LED Flash  =  Under Temp
2 Green and 2 Red LED Flash  =  Not Used
2 Green and 3 Red LED Flash  =  High Throttle Over range
2 Green and 4 Red LED Flash  =  High Throttle Under range
2 Green and 5 Red LED Flash  =  Low Throttle Over range
2 Green and 6 Red LED Flash  =  Low Throttle Under range
3 Green and 1 Red LED Flash  =  Uncalibrated throttle
3 Green and 2 Red LED Flash  =  Bad Variable Set Lo